Rapid Floor® Systems                    
ACOUSTI-MAT® CLP
SOUND RATINGS

Laboratory Sound Test: Delta IIC 19 per ASTM E 2179-03
Sound Tests Sound Tests

Field Sound Tests:

Floor System

Bare Floor,

No Acousti-Mat CLP

Rating

Acousti-Mat CLP

with WearTop

Rating

Test Numbers

8" Concrete (5th Ave. Lofts)


2" ceiling below (small scale)

47 F-IIC 57 F-IIC 30160-04-66114

8" Concrete (212 Tower Lofts)


No ceiling (small scale)

40 F-IIC 62 F-IIC 30160-05-68166-1

8" Concrete (C W Lofts)


No ceiling (14 ft. X 14 ft.)

37 F-IIC 59 F-IIC 30160-05-72550-2

F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. Actual tests above, plus additional tests are available upon request. Acousti-Mat CLP is but one component of an effective sound control system. No sound control system is better than its weakest component. Care must be taken in the installation of components of construction to assure the ultimate designed acoustical performance.