| Sound Tests | |||
| Field Sound Tests: Floor System |
Bare Floor, No Acousti-Mat LP Rating |
Acousti-Mat LP with WearTop Rating |
Test Numbers |
|
8" Concrete (5th Ave. Lofts) |
47 F-IIC | 57 F-IIC | 30160-04-66114 |
|
8" Concrete (212 Tower Lofts) |
40 F-IIC | 62 F-IIC | 30160-05-68166-1 |
|
8" Concrete (C W Lofts) |
37 F-IIC | 59 F-IIC | 30160-05-72550-2 |
| F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E 989. Actual tests above, plus additional tests are available upon request. Acousti-Mat LP is but one component of an effective sound control system. No sound control system is better than its weakest component. Care must be taken in the installation of components of construction to assure the ultimate designed acoustical performance. | |||