Rapid Floor® Systems                    
ACOUSTI-MAT® 3
SOUND RATINGS

Sound Tests Sound Tests
Acousti-Mat 3 Under-
layment
Batt
Insulation
Ceiling
Suspended
On Channel
Floor
Coverings
Ceiling
Drywall
Rating Test
Numbers
Open Beam
Yes 1 1/2 "
(38 mm)
None No Vinyl No

46 F-

IIC


02 31573.3

Yes 1 1/2 "
(38 mm)
None No Wood Floating Floor No

52 F-

IIC


02 31573.4

Yes 1 1/2 "
(38 mm)
None No None No

47 F-

STC


02 31573.6

Bare Floor over Open Beam
No

(control)

None

None No None No

33 F-

IIC


02 31573.5

           

30 F-

STC


02 31573.7
8" Cast-in-Place Concrete (203 mm) Yes

2"

(51 mm)

No No None No 65 F-IIC 03 56381.6
  Yes

2"

(51 mm)

No No None No 61 F-IIC 03 56381.5

Bare Floor, no

Acousti-mat

No

2"

(51 mm)

No No None No 36 F-IIC 03 56381.1
Steel Joist 12" Deep (305 mm) w 3/4" (19 mm) T&G Plywood subfloor Yes 1 1/2 " 
(38 mm)
Yes
(batt)
Yes
Ceramic

5/8"

(16 mm)

57 F-IIC 04-22-1
  Yes 1 1/2 " 
(25 mm)
Yes
(batt)
Yes Vinyl

5/8"

(16 mm)

57 F-IIC 04-22-2
  Yes

2 1/2"

(64 mm)

Yes
(batt)
Yes Wood

5/8"

(16 mm)

58 F-IIC 04-22-3

F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E989. F-STS (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests are available upon request.  Maxxon Underlayments and Acousti-Mat II are but two components of an effective sound control system.  No sound control system is better than its weakest component.  Care must be taken in the installation of components of construction to assure the ultimate designed acoustical performance.


©Rapid Floor® Systems | Homepage | Acousti-Mat® 3